Basic Info.
Model NO.
RV32-S2-0R4
Mathematical Model
Linear
Signal
Continuous
Function
Automatic Control
Certification
RoHS, ISO: 9001, CE
Condition
New
Customized
Non-Customized
Material
ABS
Power
0.75-11kw
Color
Gray
Weight
0.75kgs
Name
VFD
Transport Package
Carton Packing
Specification
size: 40*125*120mm
Trademark
UniMAT
Origin
China
Production Capacity
500, 000/Year
Product Description
Product Summary
*
Product configuration
Basic application functions
Compact structure design, saves installation space
Clear terminal layout marking, easier to install
Wide voltage range design ensures the adaptability of products to power network fluctuations
Advanced independent duct design, adapt to a variety of complex, harsh site environment
Strong and Weak Electrical Isolation Design
Adopt srtong & week electrical isolation Design, to avoid magnetic field
interference and increase service lift.
Heat Dissipation Structure
Independent cooling duct optimization design, from the original right
angle optimization to rounded corner, reduce the thermal disk
accumulation, greatly increase the efficiency of heat dissipation.
After heat dissipation optimization, based on the previous structure to
reduce the side heat dissipation hole , the actual protection level can be
up to IP40, the protection performance is far ahead of similar products.
. Laminated Structure
BUS capacitor board and POWER motherboard laminated design. The
BUS capacitor board is arranged in an independent cooling air duct to
effectively dissipate heat.
The new design of laminated bus can reduce stray inductance, reduce
peak voltage and protect IGBT. At the same time, compact structure,
save installation space.
High Protection Structure Design
The inlet and outlet of the copper bar are closed with rubber rings,
which can effectively isolate the external dust and corrosive gas.
Epoxy partition is added to isolate the circuit installation area and form
an independent internal space to avoid damage to the circuit board
from the external environment and extend the service life
Product configuration
Basic application functions | |
Torque raise at low frequency | To improve low frequency torque about 0.1%-30% under V/f control and sensorless speed vector control through raising voltage and torque.. |
V/F Curve | Linear type, multi-point type |
Acceleration and deceleration curve | Linear or S-shaped acceleration and deceleration; three sets of acceleration and deceleration time; acceleration and deceleration time range: 0-3200s |
Automatic Voltage Regulation (AVR) | When the grid voltage changes, it can automatically keep the output voltage constant |
Built-in PID | Convenient to realize process control under close-loop control system. |
DC braking | DC braking range: 0.0Hz-maximum frequency; braking time: 0.0s-20.0s Braking action current value: 0%-100% |
Jog control | To realize instant start and instant stop; jog frequency setting range: 0-20Hz; jog stop type: freedom/DC brake |
Frequency Hopping | Available to set three jump frequency points and related jump frequency ranges |
Multi-speed | Up to 15 operating frequencies can be set via logic input terminals |
Input Sum | The algebraic operation result of 2 analog inputs is used as the frequency setting, making the frequency setting more flexible |
2 sets of motor parameter switching | Two sets of motor parameters can be set and switched freely to match the currently driven motor |
Inverter protection | Input phase failure, output phase failure, under load monitor, over torque, under voltage, over current, over heat, short circuit among three phases |
Motor protection | Motor overheat, motor current limiting amplitude, motor over load, motor short circuit |
Electrical characteristics | |
Input voltage | Three-phase AC, 380-480V, 50/60Hz |
Output voltage | 0-480V, 0.5Hz-400Hz |
Control Mode | V/F control for constant torque, V/F control for quadratic load, vector control without PG, Energy-saving mode |
Switching frequency | 1.5kHz - 12kHz according to junction temperature automatically reduce the switching frequency |
Overload capability | 150% rated output current for 60s, 200% rated output current for 2s |
Control signal | ||
Frequency setting signal | Integrated operating panel | Film switch (Press button), speed control knob (potentiometer) |
Outside Signal | UP/DOWN setting, analog input, multi-speed, remote keypad, serial communication | |
Start-stop control signal | Integrated operating panel | RUN, STOP buttons |
Outside Signal | Logic input terminal, remote keypad, serial communication |
Protective function | |
Inverter protection | Input phase loss protection, output phase loss protection, underload detection, over-torque protection, undervoltage protection, overvoltage protection, overcurrent protection, overheating protection, phase short circuit protection |
Motor protection | Motor thermal protection, motor current limiting, motor overload, motor short circuit |
Control circuit characteristics | ||
Available inside power supply | 5V 24V | 5V DC 5%, maximun current 10mA, it is used for benchmark potentiometer 24V DC 5%, maximum current 100mA, it is used for logic input entrance |
Analog Input | AI1 | Voltage analog input: 0-5VDC, or 0-10VDC, impedance 30kΩ Current analog input: 0/4-20mADC, impedance 250Ω Resolution: 10-bit A/D conversion Factory default setting: 0-5VDC voltage input |
AI2 | Voltage analog input: 0-10VDC, or PTC probe input Resolution: 10-bit A/D conversion | |
Logic Input | LI1-LI8 | 0-24VDC power supply Positive logic (source), negative logic (sink) are optional, the factory default is negative logic 69 functions are available, including forward, reverse, running, fault reset, multi-speed, etc. Only 6 ways below 11KW (including): LI1-LI6 |
AI1,AI2 | AI1 and Al2 could be set to logic input for RV32 frequency inverter with power below (including) 11 kW. | |
Mandatory effective input | F309 and F310 are mandatory effective input. It will guarantee the set function effective during powering on. | |
Analog Output | AO1,AO2 | Voltage analog output: 0-10V DC, minimum load impedance is 470Ω Current analog output: 0-20mA, maximum load impedance is 700Ω Resolution: 8 digital |
Logic Output | LO,CLO | Open collector, maximum current 100mA, maximum voltage 30VDC Optional for logic output or pulse output, factory default is logic output Output frequency, output current and given speed are optional |
Relay output | T1A,T1B,T1C T2A,T2B,T2C | T1A constant open, T1B constant close, T1C public Point T2A constant open, T2 B constant close, T 2C public point Touch point capacity: 5A@250VAC, 5A@30VDC Many functions optional such as fault, alarm and set frequency reach |
Serial Communication | MODBUS-RTU, 2-wire RS-485, RJ45 connection port |
Environmental characteristics | |||
Ingress protection | IP20 | environment humidity | No condensed water or drip at 5~95%, In accordance with IEC60068-2-3 Installation place Altitude |
Working temperature/storage temperature | "- 10~50ºC /- 20~60ºC | Installation place | room |
cooling method | Forced air cooling | Altitude | 1000m or below (Derating is necessary when the altitude is higher than 1000m) |
Basic application functions